Turbogenerator and hydroelectric generator servicing
50 – 165 MW turbogenerators
- Replacement of indirectly-cooled generators with air-cooled turbogenerators allowing for an increase in generator capacity.
- Rotor modernization involving retaining-ring replacement with body-mounted retaining rings made of corrosion-resistant steel.
- Complete and partial replacement of stator windings.
- Modernization of operating performance control and monitoring systems.
165 – 320 MW turbogenerators
Modernization of ТВВ-series hydrogen-water-cooled turbogenerators involving the rewinding of stator windings and a transition to ТВФ-series turbogenerators with indirect hydrogen-cooling of the stator winding and the elimination of a stator winding water-cooling system:
- TVV-165-2 to TVF-165-2
- TVV-200-2 to TVF-200-2
- TVV-320-2 to TVF-320-2
200 – 300 MW ТГВ turbogenerators
- Replacement of ТГВ-200 and ТГВ-200M generators with air-cooled or hydrogen-water-cooled generators.
- Replacement of ТГВ-300 generators with hydrogen-water-cooled generators.
- Modernization of operating performance control and monitoring systems.
200 – 500 MW turbogenerators
- Stator modernization including the replacement of lamination end zones and stator winding replacement.
- Rotor modernization involving retaining-ring replacement with new design rings made of corrosion-resistant steel.
- Stator replacement with new, modernized design stators.
- Increase in generator capacity to cover turbine modernization needs.
- Modernization of stator winding heat-monitoring equipment.
- Modernization of operating performance control and monitoring systems.
800 – 1000 MW ТВВ and ТЗВ turbogenerators
- Stator modernization including the replacement of lamination end zones and stator winding replacement.
- Complete or partial replacement of four-pole generators’ stator windings.
- Old stator replacement with new, modernized design stators.
- Modernization of stator winding heat-monitoring equipment.
- Modernization of operating performance control-and-monitoring systems.
Hydroelectric generators
- Stator replacement.
- Replacement of lamination cores and stator windings.
- Rotor pole modernization.
- Modernization of hydrogenerator thrust bearings and other bearings using composite materials.
- Modernization of operating performance control and monitoring systems.
Feedback
The required fields are indicated